The indoor unit should be installed close to the wall.
Instructions for installation and use of this product are
provided by the manufacturer.
Precautions
WARNING
If you need to relocate the air conditioner to another place, only the
qualified person can perform the work. Otherwise, it may cause
personal injury or damage.
For the air conditioner without plug, an circuit break must be
installed in the line.
Select a location which is out of reach for children and far away from
animals or plants.If it is unavoidable, please add the fence for safety
purpose.
For the air conditioner with plug, the plug should be reachable after
finishing installation.
Working temperature range
NOTICE:
5
●
Indoor side DB/WB(
°F/°C
) Outdoor side DB/WB(
°F/°C
)
Maximum cooling 89.6/73.4(32/23) 109.4/78.8(43/26)
Maximum heating 80.6/-(27/-) 75.2/64.4(24/18)
The operating temperature range (outdoor temperature) for cooling only unit is
64.4
°F
(18
°C)
~ 109.4
°F
(43
°C)
; for heat pump unit is 19.4
°F(
-7
°C)
~ 109.4
°F
(43
°C)
.
For model: GWH09KF-A3DNB4A(115V), GWH12KF-A3DNB4A(115V)
NOTICE:
●
Indoor side DB/WB(
°F/°C
) Outdoor side DB/WB(
°F/°C
)
Maximum cooling 89.6/73.4(32/23) 109.4/78.8(43/26)
Maximum heating 80.6/-(27/-) 75.2/64.4(24/18)
The operating temperature range (outdoor temperature) for cooling only unit is
5°F(
-15
°C)
~ 109.4
°F
(43
°C)
; for heat pump unit is 5
°F(
-15
°C)
~ 109.4
°F(
43
°C)
.
For model: GWH09KF-D3DNB4F(230V), GWH12KF-D3DNB4F(230V)
NOTICE:
●
Indoor side DB/WB(
°F/°C
) Outdoor side DB/WB(
°F/°C
)
Maximum cooling 89.6/73.4(32/23) 115/78.8(46/26)
Maximum heating 80.6/-(27/-) 75.2/64.4(24/18)
The operating temperature range (outdoor temperature) for cooling only unit is
5°F(
-15
°C)
~ 115
°F
(46
°C)
; for heat pump unit is 5
°F(
-15
°C)
~ 115
°F(
46
°C)
.
For model: GWH18KG-D3DNB4F(230V), GWH24KG-D3DNB4A(230V)